<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0">
  <channel>
    <title>Auteurs : Mickael Derbez</title>
    <link>https://www.peren-revues.fr/pollutionatmospherique/374</link>
    <description>Publications of Auteurs Mickael Derbez</description>
    <language>fr</language>
    <ttl>0</ttl>
    <item>
      <title>Analyses et enjeux sur la qualité de l’air intérieur</title>
      <link>https://www.peren-revues.fr/pollutionatmospherique/7742</link>
      <pubDate>mer., 05 juin 2024 10:13:40 +0200</pubDate>
      <lastBuildDate>mer., 05 juin 2024 10:13:47 +0200</lastBuildDate>
      <guid isPermaLink="true">https://www.peren-revues.fr/pollutionatmospherique/7742</guid>
    </item>
    <item>
      <title>Niveaux de particules dans les environnements intérieurs en France</title>
      <link>https://www.peren-revues.fr/pollutionatmospherique/7362</link>
      <description>L’état des connaissances actuelles sur les niveaux de particules dans les différents environnements intérieurs est présenté au niveau de la France. La contribution des sources intérieures et extérieures est variable selon l’environnement et la taille des particules considérés. Il est nécessaire de développer des études pour combler le manque de connaissances sur la pollution particulaire dans les écoles et les bureaux, sur la caractérisation de la phase organique des particules des environnements intérieurs et sur les moyens à mettre en œuvre pour se protéger des particules fines provenant de l’extérieur tout en assurant une ventilation suffisante des locaux. </description>
      <pubDate>mer., 15 mai 2024 16:26:39 +0200</pubDate>
      <lastBuildDate>jeu., 13 juin 2024 11:23:00 +0200</lastBuildDate>
      <guid isPermaLink="true">https://www.peren-revues.fr/pollutionatmospherique/7362</guid>
    </item>
    <item>
      <title>Indice de confinement de l’air intérieur : des écoles aux logements</title>
      <link>https://www.peren-revues.fr/pollutionatmospherique/5466</link>
      <description>Le Centre Scientifique et Technique du Bâtiment (CSTB) a proposé en 2007 un indice de confinement de l’air pour les salles de classe, fondé sur la mesure de la concentration en dioxyde de carbone (CO2). Sur une échelle de 0 à 5, cet indice, appelé ICONE, reflète l’adéquation du renouvellement d’air d’une pièce à sa densité d’occupation. Il prend en compte à la fois les fréquences de situation de confinement, mais également leur intensité. Appliqué à la surveillance réglementaire de la qualité de l’air dans les écoles et lieux d’accueil de la petite enfance, cet indice s’est révélé être un outil pertinent et utile aux gestionnaires soucieux d’améliorer les conditions de ventilation de leurs locaux. Le présent article montre comment cet indice conçu pour les écoles peut être appliqué à l’habitat, en insistant sur la spécificité de ce lieu de vie, les conditions d’occupation des pièces étant très différentes de celles des salles de classe. Selon l’état d’occupation des pièces, l’état des portes intérieures et des fenêtres, ouvertes ou fermées, l’indice de confinement est très différent d’un logement à l’autre. Les chambres sont systématiquement plus confinées que les séjours. Un indice de confinement relatif à l’ensemble du logement exige des mesures dans les différentes pièces. Aussi, en première approche, il est proposé de se limiter au confinement de l’air dans la chambre principale du logement, en période nocturne, sur une durée d’une semaine. An air stuffiness index for classrooms, based on the measurement of the carbon dioxide concentration (CO2), was developed in 2007 by the scientific and technical center for building (CSTB). So-called ICONE, the index ranges from 0 to 5 and reflects the balance between air exchange rate and room’s occupancy density. It takes into account both the occurrence and the intensity of CO2 concentrations. ICONE is now used in the mandatory control of indoor air quality in schools and nurseries. It is a relevant and useful tool for building managers to improve ventilation conditions. This paper presents how this index can be applied to housing, considering the fact that rooms types and occupancies are very different from classrooms. The air stuffiness index may be rather different from one dwelling to another, because of different occupancy conditions and various states of indoor doors and windows, opened or closed. The air in the bedrooms is generally stuffier than in living rooms. Applying the index at the whole dwelling scale is challenging. By default, it is suggested to assess the air stuffiness only in the main bedroom, during the night over one week. </description>
      <pubDate>mer., 30 mars 2016 14:19:47 +0200</pubDate>
      <lastBuildDate>mar., 23 mai 2017 16:08:51 +0200</lastBuildDate>
      <guid isPermaLink="true">https://www.peren-revues.fr/pollutionatmospherique/5466</guid>
    </item>
    <item>
      <title>Chemical and mineralogical composition and sources of urban atmospheric particles, specially sulphates- A study at Tours (France)</title>
      <link>https://www.peren-revues.fr/pollutionatmospherique/1907</link>
      <description>In order to reconstruct the formation mechanism of the sulphated black crusts found on the tuffeau and stained glass windows of Saint-Gatien Cathedral in Tours, a study was performed on the particulate content of the atmosphere in the town, based on two sampling campaigns that took place during December 1994 and July-August 1995. The Black Carbon (BC) in air was continuously measured by means of an aethalometer. Total suspended particles were sampled both day and night by air filtration through Nuclepore membranes. The analysis of eight filters by Analytical Scanning Electronic Microscopy (ASEM) allowed the classification of particles of more than 1 μm into six categories (marine, terrigenous, mixture of marine and terrigenous, S bearing terrigenous, anthropogenic, biogenic) (+ « undeterminated »).Aethalometry and analysis of filters by X-Ray Fluorescence (XRF) indicated S, BC and Na to be the main elements present in the particles of Tours: S in summer, BC and Na in winter. Geochemical calculations show S to be of dual origin, mainly anthropogenic (Sexœss) and, to a lesser extent, marine (Smarine). The unexpected contribution of the marine natural source is confirmed by the high levels of Na, a typical marine element, also measured sporadically on the site. This phenomenon is linked to the arrival of oceanic air masses in low pressure conditions from the south-western sector and is characterised by a significant amount of marine particles in the form of crystals of halite (NaCI) and polyhalite (K2MgCa2(SO4)4,2H2O) containing Smarine· The contribution of the anthropic source is most frequently predominant, particularly in periods of strong atmospheric stability characterised by the absence of wind and in winter, in strongly anticyclonic conditions. Such pollution episodes are characterised by the abundance of anthropogenic particles and Sexcess is present in the form of ammonium sulphates, principally mascagnite ((NH4)2SO4). The BC is emitted primarily by automobiles and, when present, is mainly in the typical form of microsoot particles.Thus, the sulphates deposited on the tuffeau and stained glass windows and accumulating in the areas sheltered from rainwater must be taken into account in determining the mechanism of formation of the gypsum cement of the black crusts. Afin de reconstituer le mécanisme de formation des croûtes noires sulfatées recouvrant le tuffeau et les vitraux de la cathédrale Saint-Gatien de Tours, une étude du contenu particulaire de l'atmosphère de cette ville a été réalisée à partir de deux campagnes de prélèvements atmosphériques effectuées en décembre 1994 et juillet-août 1995. La concentration de l'air en Black Carbon (BC) a été mesurée en continu au moyen d'un aethalomètre. L'échantillonnage des particules totales a été réalisé le jour et la nuit par filtration d'air au travers de membranes Nucléopore. L'analyse de huit filtres par microscopie électronique analytique en balayage a permis d'établir un classement des particules supérieures à 1 μm en six catégories (marines, terrigènes, marines+ terrigènes, terrigènes + S, anthropogéniques, biogéniques) (+« indéterminées »).L'aethalométrie et l'analyse des filtres par spectrométrie de fluorescence X indiquent que S, BC et Na sont les éléments majeurs dans les aérosols de Tours : S en été, BC et Na en hiver. Les calculs géochimiques indiquent que S a une double origine, principalement anthropique (Sexœs) et dans une moindre mesure marine (Smann&amp;gt;·La contribution inattendue de cette source naturelle marine est confirmée par les fortes teneurs en Na, élément typiquement marin, mesurées ponctuellement. Ce phénomène est lié à l'arrivée de masses d'air océaniques en situation dépressionnaire de secteur sud-ouest et se caractérise par une proportion importante de particules marines sous forme de cristaux de halite (NaCI) et de polyhalite (K2MgCa2(SO4)4,2H2O) contenant le Smarin. La contribution de la source anthropique prédomine le plus souvent, particulièrement en période de forte stabilité atmosphérique caractérisée par l'absence de vent et en hiver, en situation fortement anticyclonique. Ces épisodes de pollution sont caractérisés par l'abondance des particules anthropogéniques et Sexœs se présente sous la forme de sulfates d'ammonium, principalement de la mascagnite ((NH4)2SO4). Le BC est émis principalement par les automobiles et se présente sous la forme typique de microsuies.Ainsi ces sulfates, qui se déposent sur le tuffeau et les vitraux et qui s'accumulent dans les zones abritées des pluies, doivent être pris en compte pour déterminer le mécanisme de formation du ciment gypseux des croûtes noires. </description>
      <pubDate>lun., 10 juin 2013 15:07:45 +0200</pubDate>
      <lastBuildDate>ven., 13 nov. 2015 13:37:42 +0100</lastBuildDate>
      <guid isPermaLink="true">https://www.peren-revues.fr/pollutionatmospherique/1907</guid>
    </item>
    <item>
      <title>Ventilation dans les logements,les écoles et les crèches</title>
      <link>https://www.peren-revues.fr/pollutionatmospherique/358</link>
      <description>Lʼarticle décrit les situations réelles de ventilation des habitations, écoles et crèches en France, telles quʼelles ont été observées in situ ainsi que leurs impacts sur la qualité de lʼair intérieur de ces espaces. La moitié du parc des logements a été construite avant 1967. 35 % des logements sont équipés de VMC et 34,5 % de ventilation naturelle par grilles ou par conduits. Le comportement de lʼoccupant joue un rôle déterminant sur la ventilation : lʼouverture des fenêtres et la perméabilité à lʼair sont les postes prépondérants du renouvellement dʼair par rapport aux systèmes de ventilation tels quʼils sont mis en oeuvre. La moitié du parc des écoles a été construite avant 1970 ; alors que la moitié du parc des crèches, après 1995. 85 % des écoles sont dépourvues de systèmes de ventilation, alors que 49 % des crèches ont une VMC. Les niveaux de confinement de lʼair dans les écoles et les crèches sont préoccupants dans 1 salle sur 5, traduisant ainsi des conditions dʼaération insuffisantes. Les crèches sont moins confinées (1 salle sur 20) que les écoles élémentaires (1 salle sur 3). The paper describes the actual conditions of ventilation of French dwellings, schools and day-care centres, as were observed in situ. Their impacts on indoor air quality of the built environment are also presented. Half the housing stock was built before 1967. 35% are equipped with mechanical ventilation system and 34.5% with natural ventilation system (grilles or passive stack ventilation). The occupant behaviour plays a key role on ventilation: windows opening and building air leakage play an important part in air renewal rate unlike ventilation system as they are implemented. Half the school stock was built before 1970, while half the day-care centre stock, after 1995. 85% of schools have no mechanical ventilation system, while 49% of day-care centres have one. The air stuffiness levels of schools and day-care centres are critical in one room out of five reflecting very poor ventilation conditions. The day-care centres are less stuffy (one room out of twenty) than the elementary schools (one out of three). </description>
      <pubDate>ven., 25 janv. 2013 14:41:43 +0100</pubDate>
      <lastBuildDate>ven., 25 janv. 2013 14:41:43 +0100</lastBuildDate>
      <guid isPermaLink="true">https://www.peren-revues.fr/pollutionatmospherique/358</guid>
    </item>
  </channel>
</rss>